Sign In | Join Free | My himfr.com
Home > Pepperl+Fuchs Parts >

Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier

Xiamen Changxuyuan Trading Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers
     
    Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers
    • Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers
    • Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers
    • Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers
    • Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers
    • Buy cheap Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier from wholesalers

    Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier

    Ask Lasest Price
    Brand Name : Pepperl+Fuchs
    Model Number : KFD2-UFC-EX1.D 231194
    Certification : COO & COC
    Price : $130
    Payment Terms : T/T,Alipay,Paypal
    Supply Ability : 99+
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier

    Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier


    1. Overview of the Pepperl+Fuchs KFD2-UFC-EX1.D 231194

    The Pepperl+Fuchs KFD2-UFC-EX1.D 231194 is a single-channel frequency conversion safety barrier from the Pepperl+Fuchs K-System series, designed for Zone 0 hazardous locations. It isolates and converts frequency signals (1 mHz…5 kHz) from NAMUR sensors or dry contacts into 0/4…20 mA analog outputs, while also providing two programmable relay alarm points. Its 40 mm-thick DIN rail enclosure (40 × 119 × 115 mm, IP20) allows for minimal space in cabinets. Its wide operating temperature range of -20…+60°C ensures reliable operation in offshore platforms, oil and gas storage and transportation, and chemical plants.

    The device is internationally certified to ATEX / IECEx Ex ia IIC T4 Ga and Ex ia IIIC T135°C Da, providing reliable isolation between intrinsically safe circuits and larger systems. Powered by 24 V DC (20…30 V), with a typical power consumption of 100 mA, it can be plugged directly into a Power-Rail power rail for hot swapping without downtime. Parameters such as range, alarm value, and filter time can be set in seconds using the panel knob or PC software. The LED displays input frequency, relay status, and line faults in real time, significantly reducing commissioning and maintenance time.


    2. Core Features:

    1. Basic Parameters
    • Function Type: Single-channel frequency conversion barrier
    • Explosion Protection Classification: ATEX / IECEx Ex ia IIC T4 Ga, Ex ia IIIC T135°C Da
    • Input Specifications: NAMUR sensor or dry contact in accordance with EN 60947-5-6, pulse width ≥ 50 µs
    • Input Frequency: 1 mHz to 5 kHz (programmable)
    • Analog Output: 0/4 to 20 mA, load 0 to 550 Ω, resolution 14 bits
    • Switching Output: Two changeover relays, contact rating 40 V DC / 2 A (resistive), can be used as overspeed/underspeed alarms
    • Power Supply: 20 to 30 V DC, typical power consumption 2.4 W, supports Power-Rail rails
    • Electrical Isolation: Input/output/power three-way isolation, isolation voltage ≥ 2.5 kV AC
    • Operating Temperature: -20 to +60°C °C, humidity ≤ 95% RH (non-condensing), IP20, DIN rail mount
    • Dimensions and Weight: 40 × 119 × 115 mm, approximately 150 g
    2. Core Functions
    Frequency to Current Linear Conversion: The range start and end points can be set arbitrarily within 1 mHz to 5 kHz using the front panel knob or PC software, with a linear output of 0/4 to 20 mA.
    Programmable Trip: Two relay groups can independently set upper and lower alarm limits, start delay, and hysteresis, enabling overspeed, underspeed, or stall interlocks.
    Fault Monitoring: Real-time detection of short circuits, disconnections, and overloads, LED status indication, and relay fault outputs, meeting SIL2/IEC 61508 requirements.
    Maintenance-Free: Hot-swappable and with a centralized 24 V power supply, replacement or expansion can be performed without downtime.
    3. Typical Applications
    • Petroleum/Chemical Industry: Speed ​​monitoring and interlock protection for pumps and compressors in Zone 0. • Pharmaceuticals/Food: Blockage and break alarms for powder conveyor belts.
    • Wind Power/Rail Transit: Pitch motor and cooling fan speed feedback and overspeed protection.


    3. Product details pictures



    4. Related products

    KFD2-UFC-1.DKFU8-UFC-EX1.D
    KFU8-UFC-1.DKFD2-DWB-EX1.D
    KFA6-DWB-EX1.DKFD2-CRG-EX1.D
    KFD2-CRG-1.DKFU8-CRG-EX1.D
    KFU8-CRG-1.DKFD2-GUT-EX1.D
    KFU8-GUT-EX1.DKFD2-SL2-EX1.B
    KFD2-SL2-EX2.BKFD0-SD2-EX1.1045
    KCD2-SR-EX1.LBKFD0-SD2-EX2.1045
    KCD2-SR-EX2.LBKFD2-SOT-EX1.LB
    KFD2-SOT-EX2.LBKCD2-SON-Ex2.R3

    Quality Pepperl+Fuchs KFD2-UFC-EX1.D 231194 24VDC Single Channel Frequency Conversion Safety Barrier for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xiamen Changxuyuan Trading Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)